Tank Volume Calculator
Calculate water tank, aquarium, or storage container volume instantly.
How to Use This Calculator
Formula:
Vertical Cylinder: V = π × r² × h | Horizontal Cylinder Filled Volume = [r² × cos⁻¹((r − d)/r) − (r − d) × √(2rd − d²)] × L | Rectangular: V = L × W × H
- Select your tank geometry: Vertical Cylinder, Horizontal Cylinder (oil/fuel tank), Rectangular Prism (water cistern), Spherical, or Elliptical.
- Input the internal physical dimensions: diameter/radius and length/height (in inches, feet, centimeters, or meters).
- Enter the current measured liquid fill depth (dipstick reading from bottom to fluid surface).
- Select your output volume units: US Gallons, Imperial Gallons, Liters, Cubic Meters, or Oil Barrels (42 gal).
- Review total internal tank capacity, active filled liquid volume, remaining unfilled capacity, and percentage full.
Frequently Asked Questions
In a vertical cylinder, the liquid volume increases linearly with fill depth. In a horizontal cylinder, however, the circular cross-section varies continuously with height. At the bottom and top of the tank, a 1-inch rise in liquid level represents a much smaller volume than a 1-inch rise near the midpoint where the tank is widest. Consequently, calculating partial fill requires circular segment trigonometry involving inverse cosines.
Standard volumetric conversion factors include: 1 US Liquid Gallon = exactly 231 cubic inches; 1 cubic foot = approximately 7.4805 US Gallons; 1 cubic meter = 1,000 liters (or 264.172 US Gallons); and 1 standard petroleum oil barrel (bbl) = exactly 42 US Gallons.
Industrial horizontal pressure vessels and transport tankers feature convex curved ends (such as ASME flanged and dished, torispherical, or 2:1 elliptical heads) to withstand internal pressure. These curved heads add additional fluid volume beyond the cylindrical shell, typically adding 5% to 15% to total tank capacity.
Ullage (or outage) is the empty vapor space intentionally preserved above the liquid level in a storage tank. Environmental and fire safety codes (like NFPA 30) mandate maintaining a minimum 5% to 10% unfilled ullage buffer to accommodate thermal expansion of liquids as ambient temperatures fluctuate, preventing tank rupture or vent spills.
A standard residential 275-gallon oval heating oil tank (typically measuring 60 inches long, 44 inches high, and 27 inches wide) has an actual usable working fill capacity of approximately 250 to 255 gallons to preserve the necessary expansion safety ullage at the top.
One US gallon of fresh water weighs approximately 8.34 pounds (1 kilogram per liter). When designing structural pads or supports for a 1,000-gallon water tank, engineers must accommodate a live water weight of 8,340 pounds (over 4.1 US tons) plus the weight of the tank itself.